Outdoor cabinet air conditioner achieves heat absorption refrigeration through compression refrigeration, transferring the heat emitted by the equipment inside the cabinet to the outside of the cabinet in a closed environment. The high temperature, dust and other dirty gases outside the cabinet will not enter the interior, thus solving a series of problems caused by fan heat dissipation. The interior of the cabinet can always maintain an ideal temperature environment of around 30 ℃, effectively ensuring the stability of electronic equipment.
◆AC220V 60HZ power input
◆1000W cooling capacity (optional configured with heater)
◆High efficiency rotary compressor:Reliable & energy saving
◆LED display:Parameters setting and operation display
◆IP55 High protection level:Application in outdoors perfectly
◆Wide operating temperature range:Adapt to all conditions
  • AC110-2/A10NA1E

  • Cytech

Availability:
facebook sharing button
twitter sharing button
line sharing button
wechat sharing button
linkedin sharing button
pinterest sharing button
whatsapp sharing button
sharethis sharing button

Outdoor cabinet air conditioner is actively cooling by compressor ,it will remove the heat inside the cabinet to outside. It also can keep the dust and heat outside the cabinet,avoiding problems from using fan. The temperature inside the cabinet can be maintained at an ideal temperature for electrical components which effectively guarantee the stability of the electronic equipment and improves the reliability of the whole system.

1000W outdoor cabinet air conditioner specifications

1.Technical parameter

Item Name Technical parameter
1 Model AC110-2/A10NA1E
2 Main power supply 1~220VAC±15% 60Hz 1 phase
3 Cooling capacity(Rated) 1000W@L35/L35
4 Power consumption(Rated) 430W@L35/L35
5 Heating capacity(optional) 1000W
6 Air flow 230m3/h
7 Cooling current (rated/Max.) 2.0A/3.5A
8 Work temp. range -40℃~+55℃
9 Noise 60dB(A)
10 IP Grade IP55,NEMA 4,NEMA 4X
11 Net Weight 25KG
12 Refrigerant R134a

Note:@L35/L35 is Internal temperature 35℃, ambient temperature 35℃

2. Thermal cycle and air flow

Cooling: the high-pressure refrigerant liquid in the system enters the evaporator and evaporates to absorb heat of the air in the cabinet, so the air is cooled, and the refrigerant that evaporates into gas in the evaporator is inhaled by the compressor and compressed into the high-pressure and high-temperature refrigerant gas, which enters the condenser and cooled to refrigerant liquid, and then re-enters the evaporator to cool the indoor air, and circulates accordingly.

outdoor cabinet air conditioner cycle

Outdoor cabinet air conditioner features

◆It also can keep the dust and heat outside the cabinet,avoiding problems from using fan;

◆The temperature inside the cabinet can be maintained at an ideal temperature for electrical components which effectively guarantee the stability of the electronic equipment and improves the reliability of the whole system;

◆Compact structure ,reasonable design and easy maintenance;

◆Digital temperature controller and high precision of temperature control;

◆The heating function and the hydrogen function is optional;

◆Remote measuring, remote communication, remote control, which can realize multiple automatic protection and comprehensive self-testing function;

◆Dry contact alarm output,NO/NC optional;

◆LED display, all the settings can changed at the field

◆Multiple self-protection design & visible monitoring interface, RS485 communication port (MODBUS-RTU);

◆Fit for harsh condition (T3), R134a refrigerant .

Outdoor cabinet air conditioner Flexibility

Cooling capacity ranges from 300w to 5000w

Voltage range :AC220V 50HZ,AC220V 60HZ,60HZ , AC110V60HZ ,DC48V

Widely used for outdoor telecom cabinets ,battery cabinets,elecric cabinets and industry control cabinets etc.

Remote monitoring system supported, communication protocol is RS485

More option for outdoor cabinet air conditioner

1.220VAC 50HZ power outdoor cabinet air conditioner

Model Voltage Nominal cooling capacity(W) (L35/L35) Nominal cooling capacity(Btu/hr) (L35/L35) Power consumption(W)(L35/L35) IP Grade Heater (W)(option) Internal air flow (m3/h) Refrigerant Noise (dbA)
CYAC103-2 220VAC 50Hz 300 1020 170 IP55,NEMA 4, NEMA 4X 500 100 R134a 56
CYAC104-2 220VAC 50Hz 400 1360 215 IP55,NEMA 4, NEMA 4X 500 110 R134a 56
CYAC105-2 220VAC 50Hz 500 1700 280 IP55,NEMA 4, NEMA 4X 500 120 R134a 56
CYAC110-2 220VAC 50Hz 1000 3400 430 IP55,NEMA 4, NEMA 4X 1000 230 R134a 62
CYAC112-2 220VAC 50Hz 1200 4080 498 IP55,NEMA 4, NEMA 4X 1000 240 R134a 62
CYAC113-2 220VAC 50Hz 1300 4440 532 IP55,NEMA 4, NEMA 4X 1000 260 R134a 63
CYAC115-2 220VAC 50Hz 1500 5100 600 IP55,NEMA 4, NEMA 4X 1000 300 R134a 63
CYAC120-2 220VAC 50Hz 2000 6800 745 IP55,NEMA 4, NEMA 4X 1000 500 R134a 63
CYAC125-2 220VAC 50Hz 2500 8500 846 IP55,NEMA 4, NEMA 4X 2000 560 R134a 63
CYAC130-2 220VAC 50Hz 3000 10200 1240 IP55,NEMA 4, NEMA 4X 2000 720 R134a 63
CYAC135-2 220VAC 50Hz 3500 11900 1360 IP55,NEMA 4, NEMA 4X 2000 1250 R134a 63
CYAC150-2 220VAC 50Hz 5000 17000 2000 IP55,NEMA 4, NEMA 4X 2000 2300 R134a 63

2.220VAC 60HZ power outdoor cabinet air conditioner

Model Voltage Nominal cooling capacity(W) (L35/L35) Nominal cooling capacity(Btu/hr) (L35/L35) Power consumption(W)(L35/L35) IP Grade Heater (W)(option) Internal air flow (m3/h) Refrigerant Noise (dbA)
CYAC103-2 220VAC 60Hz 300 1020 170 IP55,NEMA 4, NEMA 4X 500 100 R134a 56
CYAC104-2 220VAC 60Hz 400 1360 215 IP55,NEMA 4, NEMA 4X 500 110 R134a 56
CYAC105-2 220VAC 60Hz 500 1700 280 IP55,NEMA 4, NEMA 4X 500 120 R134a 56
CYAC110-2 220VAC 60Hz 1000 3400 430 IP55,NEMA 4, NEMA 4X 1000 230 R134a 62
CYAC112-2 220VAC 60Hz 1200 4080 498 IP55,NEMA 4, NEMA 4X 1000 240 R134a 62
CYAC113-2 220VAC 60Hz 1300 4440 532 IP55,NEMA 4, NEMA 4X 1000 260 R134a 63
CYAC115-2 220VAC 60Hz 1500 5100 600 IP55,NEMA 4, NEMA 4X 1000 300 R134a 63
CYAC120-2 220VAC 60Hz 2000 6800 745 IP55,NEMA 4, NEMA 4X 1000 500 R134a 63
CYAC125-2 220VAC 60Hz 2500 8500 846 IP55,NEMA 4, NEMA 4X 2000 560 R134a 63
CYAC130-2 220VAC 60Hz 3000 10200 1240 IP55,NEMA 4, NEMA 4X 2000 720 R134a 63
CYAC135-2 220VAC 60Hz 3500 11900 1360 IP55,NEMA 4, NEMA 4X 2000 1250 R134a 63

3.110V 60HZ power outdoor cabinet air conditioner

Model Voltage Nominal cooling capacity(W) (L35/L35) Nominal cooling capacity(Btu/hr) (L35/L35) Power consumption(W)(L35/L35) IP Grade Heater (W)(option) Internal air flow (m3/h) Refrigerant Noise (dbA)
CYAC103-2 110VAC 60Hz 300 1020 170 IP55,NEMA 4, NEMA 4X 500 100 R134a 56
CYAC104-2 110VAC 60Hz 400 1360 215 IP55,NEMA 4, NEMA 4X 500 110 R134a 56
CYAC105-2 110VAC 60Hz 500 1700 280 IP55,NEMA 4, NEMA 4X 500 120 R134a 56
CYAC110-2 110VAC 60Hz 1000 3400 430 IP55,NEMA 4, NEMA 4X 1000 230 R134a 62
CYAC112-2 110VAC 60Hz 1200 4080 498 IP55,NEMA 4, NEMA 4X 1000 240 R134a 62
CYAC113-2 110VAC 60Hz 1300 4440 532 IP55,NEMA 4, NEMA 4X 1000 260 R134a 63
CYAC115-2 110VAC 60Hz 1500 5100 600 IP55,NEMA 4, NEMA 4X 1000 300 R134a 63

Other outdoor cabinet climate control

Name Specification
Air conditioner AC220V 50HZ,AC220V 60HZ,AC110V 60HZ or DC48V, cooling capacity from 300W-5000W.
Heat exchanger DC48V,40W/K-200W/K
Combined air conditioner & heat exchanger

AC220V 50HZ and DC48V

1500W&80W/K

TEC DC48V, 200W-1200W
Fan AC220V 50HZ,AC220V 60HZ,AC110V 60HZ or DC48V

How to choose outdoor telecom cabinet climate control system?

◆acceptable temperature range for your equipment;

◆Heat load of equipment;

◆The highest local ambient temperature;

◆Noise Level;

◆Future Expansion;

By carefully considering these factors, you can select a cabinet climate control system that meets the specific needs of your equipment and environmental conditions.

Normative standard

◆ <GB 4208>  Enclosure Protection Class

◆ <GB 4706.1> Safety of household and similar electrical appliances

◆ <GB9237-2001> Mechanical refrigerating systems used for cooling and heating-safety requirements

◆ <GB/T 17626.8> Electromagnetic compatibility - Testing and measurement techniques -Power frequency magnetic field immunity test

Other fault analysis and processing


Fault state

Analysis of the reasons

Solutions

Power on the switch, the cabinet temperature is too high but the air conditioner is not

working.

1)Power failure or no power.

2)The cooling set temperature is higher than the cabinet temperature.

3)System fault.

1)Check the power supply and the electric circuit.

2)Setting cooling temperature

according to the needs.

3)Please contact professional

maintenance.

The air conditioner is running but the cooling effect is not good.

1)The cooling capacity of the air conditioner is not match with the load.

2)The ambience temperature is too high.

3)Other system fault.

1)To add or choose another air conditioner according to the load.

2)Ensure the machine is used in the correct range.

3)Please contact professional maintenance.

The machine is stopping suddenly, and the electric system is normal.

1)The cabinet temperature greater than or equal to the cooling set temperature.

2)Other system fault.

1)Setting cooling temperature according to the needs.

2)Please contact professional maintenance.


Warranty

Warranty Period

The product guarantee period is 12 months from product up-running time or Max. 18 month

from product delivery date, or depends on agreement with the company.

Warranty Coverage

During the warranty period, all belong to the product itself quality problems caused by fault, the company will be free for you to repair; Household repair is required to provide the product label.

But by any of the following causes the failure does not belong to our warranty.

1.Out of the Warranty period

2.Cannot provide the product label(the product label is on the nameplate);

3.Because of the abnormal condition or environment ,or the instructions specified in the inappropriate installation, maintenance or operation causes the fault;

4.Not caused by equipment failure, caused by user’s other equipment or software.

5.User changed or disassembled by themselves ,or maintained by the person without authorization.

6.Caused by force majored such as fires, earthquakes, floods and other damage to the fault.



Outdoor cabinet air conditioner production video


Previous: 
Next: 

Consult Your Cytech Outdoor Telecom Cabinet Experts

Consult Your Cytech Experts
PROUDCTS
SUPPORT
QUICK LINKS
CONTACT US
    info@cytech.org.cn
   +86 13775296911
   weidun2013
    #5 Fuling Road, Zhonglou district, Changzhou, Jiangsu, China
COPYRIGHT © 2023 CHANGZHOU CHEN TONG YUAN COMMUNICATION EQUIPMENT CO.;LTD ALL RIGHTS RESERVED.